find com17 115200 rcvr none
pause 15

SEND RCVR "COM COM1 115200 N 8 1 N OFF ON\r"
SEND RCVR "COM COM2 115200 N 8 1 N OFF ON\r"
pause 20

;Standard settings
send rcvr "externalclock ocxo 10mhz\r"  
send rcvr "clockadjust disable\r" 
send rcvr "SinBandWidth 0.1 0.0\r"  
send rcvr "SinTECCalibration 1\r"  

; Owl Centre setup, dual independent loggers, params and Rinex COM1, params only COM2
send rcvr "com1 CPOFFSET 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0\r"
send rcvr "com2 CPOFFSET 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0\r"
send rcvr "log com1 ismrb onnew\r"
send rcvr "log com2 ismrb onnew\r"
send rcvr "log com1 rxstatuseventa once\r"
send rcvr "log com2 rxstatuseventa once\r"
send rcvr "log com1 versionb once\r"
send rcvr "log com2 versionb once\r"
send rcvr "log com1 rawephemb onchanged\r"
send rcvr "log com2 rawephemb onchanged\r"
send rcvr "log com1 bestposB ontime 60.0\r"
send rcvr "log com1 rangecmpb ontime 30.0\r"
send rcvr "ecutoff 0.0\r"

SEND RCVR "SAVECONFIG\r"